| Title |
Evaluation of the Electrical Resistance between ITO/black interlayer/Bus electrodes in a Plasma Display Panel |
| ISSN |
1738-8228(ISSN), 2288-8241(eISSN) |
| Keywords |
plasma display panel; electrical resistance; black interlayer; ITO; bus |
| Abstract |
Black interlayer was introduced into between ITO and Bus electrodes to enhance a bright room contrast ratio of a plasma display panel. To measure the electrical resistance of the black interlayer, we designed two test patterns, type I and type II, of which type II pattern was successful. Using type II test pattern, the electrical resistance of the black interlayer was measured to be 300Ω for 2 μm thickness case and infinitely high for 4, 6 μm thickness. This result shows that electrical resistance of the black interlayer in the ITO/black interlayer/Bus electrodes structure is a critical parameter which determines the electrical characteristics of the PDP. |